privacy. The report is shown in the Masking Equalizer control box
and is stated in terms of change to the Privacy Index. A change
must be at least 1% for it to display. The calculation is performed as
specied in “ASTM International; Designation: E1130-02, Standard
Test Method for Objective Measurement of Speech Privacy in Open
Ofces Using Articulation Index”.
Figure 15: Operations Section with the equalizers block displayed after a higher
level password has been entered.
ENFD (Emitter Network Fault Detection)
The ENFD is a feature used after installation to monitor the status
of the emitter cable runs. As shown on the screen, the installation
should be complete without defect before the ENFD feature is
enabled. The installation is complete by following the steps for
installation, ensuring all the emitters are working and there are no
error codes displayed.
The ENFD feature will start taking measurements of the cable runs
after power is applied. It will take 15 minutes after booting to learn
the emitter network and determine the steady state of the system.