www.csmqt.com/qtprosupport
11
If you are using a browser, subsequent
adjustments are automatic and you may
disregard the information below.
• If you are managing Qt PRO™ from the front control
panel, set the unit’s masking volumes to be 6-10 lev-
els lower on Day 1. Using the control panel, make
a +2 level adjustment before each workday begins,
until you reach the permanent masking volumes.
POST-INSTALLATION HANDOFF
• Perform a final walkthrough. Once you are satisfied
with the system’s performance complete the
Installer section of the Settings Record (see back of
Guide) and record your contact information on the
inside door label. Leave the completed Guide with
the unit.
• Lock the control panel by switching the panel lock
toggle switch to “Locked”. Close and lock the box.
Hand the key to the administrator.
• If the unit is connected to the network, sit with
the network administrator and connect to the unit
using the Hostname or IP Address, Username and
Password. Click “HELP” to learn about operating
the unit in Networked Mode.
• If an acoustics professional is present, they
may wish to modify the tuning parameters (from
a browser).
• It is the responsibility of the administrator to ensure
that all settings are recorded. These values will be
used to reconfigure the system in the event of a
hard unit failure. Settings are automatically restored
upon recovery from a power failure.
PRINT SETTINGS: A complete settings record
can be printed from the “Print Settings” link on the
Administration page of the Qt PRO™ System
Monitoring and Control application.
It is advisable to print out a final record of settings and
keep a copy with the unit.